If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Green Power Solutions srl Via Greto di Cornigliano 6R - 16152 Genova , Italy Phone: +39-010-659 1869 Fax: +39-010-659 1870 Web: www.gpsemi.it E-mail: info@gpsemi.it GOA9xx04C THREE PHASE AC-SWITCH Fuse protection Blown fuse indicators with microswitch Over temperature switches Fan loss detection circuit Snubber for SCR's protections Compact design LINE VOLTAGE UP TO 500V RMS OUTPUT CURRENT 450A GOA94004C GOA95004C Line to line voltage 400 500 Characteristic IRMS VINS (rms) RMS output current Insulation voltage Conditions Value 450 A 3000 V Value 450 A 3000 V THYRISTOR TRIGGERING CHARACTERISTICS VGT IGT dV/dt VRRM Gate trigger voltage Gate trigger current Critical rate of rise off-state voltage Blocking Voltage Tj = 25 C, VD = 5 V Tj = 25 C, VD = 5 V Tj= 125 C Tj = 125 C 3V 300 mA 1000 V/us 1200 V 3V 300 mA 1000 V/us 1600 V FUSE TYPE SIBA 2062432.630 VNF INF PVF It Rated voltage Rated current Power loss Total I2t At rated current At 660V 690 V 630 A 94 W 300 kA2s 690 V 630 A 94 W 300 kA2s MECHANICAL AND THERMAL CHARACTERISTICS Width Depth Height Mass Ta max Tstg Max amb. op. Temp. Storage temperature 400 mm 340 mm 500 mm 30 Kg 40 C -40/ +60 C 450 mm 340,5 mm 500 mm 30 Kg 40 C -40/ +60 C Document GOA9xx04CT002 THREE PHASE AC-SWITCH GOA9xx04C The part numbering system is reported at the beginning of the Open Assembly section. Customisations are available on request. Please contact factory. In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. Document GOA9xx04CT002 THREE PHASE AC-SWITCH GOA9xx04C FAN BOARD FAN 1 FAN 2 BLUE GREEN/YELLOW BLUE GREEN/YELLOW BROWN BLACK NO COM NC AC AC BROWN BLACK FAN CAPACITOR FAN CAPACITOR 1 1 31 32 U3 PE V3 Cooling: Fan type: Number of fans: Voltage: Current: Frequency: Noise: single phase axial 2 230 V 0.4 A 50/60 Hz 62 dBA 2 U3-V3: MAIN SUPPLY PE: GROUND CONNECTION (GND) 31-32: FAN BOARD CONTACT (CLOSED WHEN FAN RUNNING) In the interest of product improvement Green Power Solutions reserves the right to change any specification given in this data sheet without notice. Document GOA9xx04CT002 2 |
Price & Availability of GOA94004C |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |