|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Filename: tfs 299.doc Version 1.9 13.10.2006 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 02 C dBm Filter specification TFS 299 1/5 625 || -5,3 pF 520 || -5,1 pF Characteristics Remark: The nominal frequency fN is fixed at 299 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS 299 is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range. Data Insertion loss (reference level) Nominal frequency Passband Pass band ripple Bandwidth 3 dB Relative attenuation fN fN fN fN + 1,8 6,0 298,0 60,0 MHz MHz MHz MHz ... ... ... ... fN fN fN fN + 6,0 60,0 60,0 701,0 ae fN PB p-p BW typ. value 6,2 0,3 1,1 arel MHz MHz MHz MHz 23 40 45 46 0,77 p-p 95 OTR 25 TCf ** -0,036 C ppm/K 2 tolerance / limit max. 8,0 299,0 fN 80 0,5 400 dB MHz kHz dB kHz dB dB MHz max. min. dB dB dB dB s ns min. min. min. min. max. max. max. 20 35 20 20 1 1 +10 dB dB dB dB s s dBm Absolute group delay at fN Group delay ripple within PB Input power level Operating temperature range Storage temperature range Frequency inversion temperature Temperature coefficient of frequency -40 C ... + 85 C -40 C ... + 90 C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 299.doc Version 1.9 13.10.2006 VI TELEFILTER Filter characteristic 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 294.4 Filter specification TFS 299 2/5 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 298.4 magnitude in dB magnitude in dB 295.3 296.2 297.1 298 298.9 299.8 frequency in MHz 300.7 301.6 302.5 303.4 298.5 298.6 298.7 298.8 298.9 299 frequency in MHz 299.1 299.2 299.3 299.4 Construction and pin connection (All dimensions in mm) 9,3 Max. 1 2 3 4 5 6 7 8 9 10 Output Ground Ground Ground Ground Input Ground Ground Ground Ground 7,3 Max. 1 3 2 Max. TFS 299 U41 Date code 5,08 0,8 R0 ,3 0,1 0,9 Date code: U V W ... Year + week 2006 2007 2008 50 Test circuit 2,54 L1 6 1 L2 SAW C1 C2 2, 3, 4, 5, 7, 8, 9, 10 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 299.doc Version 1.9 13.10.2006 VI TELEFILTER Stability characteristics, reliability Filter specification TFS 299 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 5. ESD 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; MIL-STD-883E using coupling network of ISO 10605 and EN 6100-4-2 HBM:250V; MM:200V; CDM:V; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: Pull Off Direction 2000 min. 300 mm min. 500 mm min. 300 mm Tape (all dimensions in mm) W : 16,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,10 F : 7,50 0,10 G(min) : 0,60 P2 : 2,00 0,1 P1 : 12,00 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 0,10 Bo : 9,60 0,10 Ct : 13,5 P1 Date Code t Do Po P2 E G Ct Bo F Ko Typ PIN Marker D1 Ao W2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. G W Filename: tfs 299.doc Version 1.9 13.10.2006 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 299 4/5 Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / C max. 260C 217C max. 300 s 10 ... 30 s 30 ... 150 s Time / s Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 299.doc Version 1.9 13.10.2006 VI TELEFILTER History Version 1.6 1.7 1.8. Reason of Changes - impedances modified - date code changed and explained - tape and reel dimensions corrected - ESD limits added - Storage temperatur range added - Change remark Filter specification TFS 299 5/5 Name Steiner Steiner Strehl Date 24.03.2000 12.07.2000 17.09.2004 1.9 - Add typ. value and filter characteristic Strehl 13.10.2006 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS29906 | |
|
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |