filename: tfs 280g.doc version 1.7 03.03.2006 vi telefilter filter specification tfs 280g 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m measurement condition ambient temperature: 22 c input pow er level: 0 2 dbm source and load impedance: 50 ? terminating impedances * input: 275 ? || -7,7 pf output: 162 ? || -10,6 pf ch aracteristics remark: the reference lev e l for the relativ e attenuation a rel of tfs280g is the minimum of the pass band attenuation a min . this v a lue is defi ned as the insertion loss a e . the centre frequency f c is the arithmetic mean v a lue of the upper and low e r frequencies at the 3 db filter attenuation le v e l relativ e to the insertion loss a e . the giv en v a lues for the relativ e attenuation a rel and the group delay ripple hav e to be reached at the frequencies giv en below , ev en if the centre frequency f c is shifted due to the temper ature coefficient of frequency tc f in the operating temperature range and due to a production tolerance for the centre frequency f c . d a t a ty p. v a lue limit insertion loss a e = a min 11,3 db max. 12 db nominal frequency f n - 280,0 mhz centre frequency f c 280,0 mhz - relativ e attenuation a rel f n - 20 mhz ... f n + 20 mhz 0,8 db max. 1 db 10 mhz ... f n - 32 mhz 41 db min. 40 db f n + 32 mhz ... f n + 40 mhz 38 db min. 37 db f n + 40 mhz ... f n + 220 mhz 41 db min. 40 db group delay ripple gdr f n ? 17 mhz ... f n + 17 mhz 38 ns max. 75 ns input pow er lev e l - max. + 10 dbm operating temperature range - - 40 c ... + 85 c storage temperature range - - 40 c ... + 85 c temperature coefficient of frequency tcf -87 ppm/k - *) the terminating impedances depend on parasitics and q-v a lues of matching elem ents and the board used, and are to be understood as reference v a lues only . should there be additional questions, do not hesitate to ask fo r an application not e or contact our design team. **) ? f(h z ) = t c f (ppm/k) x (t-t 0 ) x f to (mhz) ge ne ra te d: ch ecked / a p p r o v ed : vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 280g.doc version 1.7 03.03.2006 vi telefilter filter specification tfs 280g 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m f ilter ch aracteristic 18 0 20 0 22 0 240 26 0 280 30 0 320 34 0 36 0 38 0 -7 0 -6 3 -5 6 -4 9 -4 2 -3 5 -2 8 -2 1 -1 4 -7 0 f r e q uency i n m h z m a gni t ude i n db 25 2 2 57. 6 2 63. 2 268 . 8 274 . 4 280 28 5. 6 29 1. 2 29 6. 8 30 2. 4 30 8 -1 0 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 f r equency i n m h z m a gni t ude i n db 25 2 2 57. 6 2 63. 2 268 . 8 274 . 4 280 28 5. 6 29 1. 2 29 6. 8 30 2. 4 30 8 0. 3 0. 3 6 0. 4 2 0. 4 8 0. 5 4 0. 6 0. 6 6 0. 7 2 0. 7 8 0. 8 4 0. 9 f r equency i n m h z de l a y i n s cons truc tion a nd pin c onne c t ion (all dimensions in mm) date code: y ear + w eek u 2006 v 2007 w 2008 ... 1 input rf return 2 input 3 ground 4 ground 5 output rf return 6 output 7 ground 8 ground 7 5 13 1, 8 m a x . 2, 54 0, 1 1, 1 1, 1 1 2 0 0, 64 5 -0 , 1 0 +0 , 1 5 1 3 5 7 d a t e c ode 280g u09 50 ohm test circuit c1 l 1 sa w l 2 c2 1 3, 4, 7, 8 5 6 2 vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 280g.doc version 1.7 03.03.2006 vi telefilter filter specification tfs 280g 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m stability characteristics 1. high temperature (iec 60068 -3-1) 1,000 hours at +85c 2. low temperature (iec 60068 -3-1) 1,000 hours at ? 40c 3. humidity (iec 60068 -2-78) 1,000 hours at 85% /85c 4. thermal shock ( iec60068-2-14 ) -55 c to 125c / 30 min. each / 10 cy cles 5. vibration (iec 60068 -2-6) 10 hz to 500 hz, 0,35 mm or 5g respectively , 1 octave per min, 10 cy cles per plan, 3 plans 6. shock (iec 60068 -2-27) 500g, 1 ms, half sine w a ve, 3 shocks each plane 7. reflow profile ( defined at specification ) 260c +/- 5c for 10 seconds, 2 cy cles 8. soler ability 235c +/- 5c for 15 seconds, 1 cy cle 9. pullability , distor tion according to mil-std 883 method 2004.5 condition d this filter is rohs compliant (2002/95/eg, 2005/618/eg) packin g tape & reel: iec 286 ? 3, w i th exception of value for n and minimum bending radius; tape ty pe ii, embossed carrier tape w i th top cover tape on the upper side; max. pieces of filters per reel: 3000 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao p u l l o ff d i r e c t i o n pi n m a r k e r ty p da t e c o d e ko t tape (al l di mensi ons i n mm) w : 12,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 5,50 0,05 g(min) : 0,75 p2 : 2,00 0,05 p1 : 8,00 0,1 d1(min) : 1,50 a o : 5,30 0,1 bo : 5,30 0,1 ct : 9,5 0,1 a c n w 1 w 2 r eel (all d i men s io n s in mm) a : 330 w 1 : 12,4 +2/-0 w 2 (max ) : 18,4 n(min) : 50 c : 13,0 +0,5/-0,2 the minimum bending radius is 45 mm. vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 280g.doc version 1.7 03.03.2006 vi telefilter filter specification tfs 280g 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m a i r re flow te mpe r a t ure c onditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/second > 100c betw een 300 and 600 seconds > 150c betw een 240 and 500 seconds > 217c betw een 30 and 150 seconds peak temperature max. 260c time w i thin 5c of actual peak temperature betw een 10 and 30 seconds cool-dow n rate (peak to 50c) less than 6c/second time from 30c to peak temperature no greater than 300 seconds chip-mount air reflow profile temperature / c max. 260c 217c time / s max. 300 s 10 ... 30 s 30 ... 150 s vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 280g.doc version 1.7 03.03.2006 vi telefilter filter specification tfs 280g 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m history version reason of changes name date 1.0 - new generation steiner 20.08.2002 1.1 - change temperature, add 3db passband requirement steiner 28.10.2002 - relax stop-band limit lines according to larger temperature range 1.2 - source and load impedance added steiner 07.01.2003 - passband magnitude extended to +/-20mhz - tk added 1.3 - label changed to standard label steiner 18.03.2003 1.4 - change pinning corresponding to customer demands chilla 23.04.2003 - added operating temperature range to guaranty for samples delivered w i th date code r16 1.5 - added limit line at 37 db chilla 10.07.2003 1.6 - changed development spec ification to filter specification chilla 16.10.2003 - added ty pical values - operating temperature range changed to ?40 c ... +80 c - added terminating impedances 1.7 - filter characteristics added chilla 03.03.2006 - test circuit updated - stability characteristics updated - air reflow temper ature conditions updated vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
|