1240 dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. specifications and availability subject to change. agastat catalog 1308242 issued 3-03 www.tycoelectronics.com technical support: refer to inside back cover. VTM-1 series specification grade, on-delay timing module on-delay timing mode timing from 1 to 1000 sec. 1a solid state spst-no output 0.25" (6.35) quick connect terminals universal voltage: 24 to 240vac/vdc rated to 10 million operations file e60363 file lr51332 timing mode on-delay ?VTM-1 in-line timing module is wired in series with the load circuit. time delay is initiated when power is applied to the series network. connecting a resistor across the center terminals provides tamper-proof setting of time delay from 1-1000 sec. timing specifications timing ranges: 1 to 1,000 sec. timing adjustment: time delay is set by connecting an appropriately rated resistor or potentiometer between the center two terminals. as supplied, the unit provides a nominal 1 second delay. add 10k ohm of resistance for every additional second of delay required. for example: 5 seconds = 40k ohms; 10 seconds = 90k ohms. accuracy: repeat accuracy: 2% reset time: 100 ms, max., in the timing or time-out condition. output switch data arrangement: 1 form a (spst-no). rating: 5a, inductive, at nominal operating voltage. inrush: not to exceed 10a for one cycle. max. leakage current: 4ma rms. expected electrical life: 10,000,000 operations at rated load. outline dimensions wiring diagram mechanical data mounting: screw mount in horizontal or vertical position through built-in mounting ears. termination: 0.250 in (6.35) quick connect terminals for input line, load output and timing resistor connection. weight: 3 oz. (84g) approximately. environmental data temperature range: storage: -40 c to +85 c. operating: -30 c to +65 c. input data @ 25 c operating voltage: universal: 24-240vac/vdc (19-288vac/vdc). current: 2ma (max.) required to operate timer regardless of output state. power requirement: 3w, max. transient protection: mov across input 2,000v for 11 s on line side of load. users should thoroughly review the technical data before selecting a product part number. it is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. ordering information authorized distributors are likely to stock the following: VTM-1 part number mode input voltage VTM-1 on-delay 24-240vac or vdc initial dielectric strength between active terminals and outside of case: 1,480vac for one min. notes: 1. do not operate timer without connecting load in series with line voltage. 2. for a time delay of 1 second, connect a jumper across the center two terminals.
|