tpc/ gkf - 20 0 - xs series www.gztoppower.com tel:0086-20-8 2019000 email:sales2@gztoppower.com page 1 / 4 description the rated output power of tpc/gkf-200-xs series is 200.4~201.6w input voltage range 90-264vac, output voltage : 12v,24v,48v. high reliability, pre cision,effificency , ultra-small size, no external heat sink required, stable output voltage and etc, with short circuit, over-load,over-voltage protection, widely used in telecommunications, industrial contr ol, instrument, data acquisition, signal control , new energy, security,dc motor,cnc system and other electronic systems. 200w wide input ac/dc switching power supply all specifications typical at ta=25c, nominal inpu t voltage and rated output current unless otherwise specified. output characteristics conditions conditions parameter ripple and noise,ta is ambient 0 ta 65 12v 24v 48v output voltage 150mvp-p ripple and noise,ta is ambient -25 ta 0 12v 24v 48v output voltage 200mvp-p dynamic load characterstics, -25 ta 65 12v output voltage 1.67a-16.7a < 600mv 1.67a-8.35a < 300mv 8.35a-16.7a < 300mv 24v output voltage 0.84a-8.4a < 1200mv 0.84a-4.2a < 600mv 4.2a-8.4a < 600mv 48v output voltage 0.42a-4.2a < 2400mv 0.42a-2.1a < 1200mv 2.1a-4.2a < 1200mv output adjustment range @25 12v output voltage 9v~15v 24v output voltage 20v-27v 48v output voltage 40v-53v voltage regulation accuracy@-25~65 2%@12v(11.76-12.24) / 1%@24v(23.76-24.24) 48v(47.52-48.48) line regulation@ -25~65 0.5% load regulation@ -25~65 2%@12v(11.76-12.24) / 1%@24v(23.76-24.24) 48v(47.52-48.48) temp. coefficient@-25~65 0.03%/ set-up time@25 2.0s / 4.0s ( 230vac/120vac input, full load ) @ 1 2v 16.7a output /24v 8.4a output 2.0s /4.0s ( 230vac/115vac input, full load ) @ 48 v 4.2a output hold-up time@25 12ms overshoot&undershoot@ -25~65 <5.0% features ac input 90-264 vac 100% full load burn-in test short circuit, over-load,over-voltage protection operating temperature -25 ~65 rohs complaint withstand 300vac surge input for 5 sec altitude up to 5000m high efficiency, long life and high reliability built-in active pfc,pf>0.95 selection guide part number input output efficiency @25 , typ % volatge vac) voltage vdc) pre-set voltage @25 (v) rated current a current range(a) rated power(w) rated range tpc/gkf-200-12s 220 90-264 12 12.00-12.10 16.7 0-16.7 200.4 84 tpc/gkf-200-24s 220 90-264 24 24.00-24.10 8.4 0-8.4 201.6 87 tpc/gkf-200-48s 220 90-264 48 48.00-48.10 4.2 0-4.2 201.6 87 input characteristics conditions parameter input voltage range 90vac~264vac 120~370vdc max input voltage 300vac 10s rated input voltage range 100vac~240vac frequency range 47hz~63hz toppower
tpc/ gkf - 20 0 - xs series www.gztoppower.com tel:0086-20-8 2019000 email:sales2@gztoppower.com page 2 / 4 input characteristics set-up voltage@-25~65 90vac 80% load set-up,@ -20 100% load set-up, 220vac input @ -40 input current@25 3.5a inrush current @25 50a@ 220vac cold start 60a@110vac cold start power factors@25 pf>0.98/120vac & pf>0.95/230vac (at full lo ad) protection @-25~65 conditions parameter over-power (216-360w@12v,240-360w@24v,240-363w@48v hiccup mode, auto recovery output short circuit protection long-term mode, auto recovery over-load (18-30a@12v,10-15a@24v,5-7.56a@48v) hiccup mode, auto recovery environment characteristics conditions parameter operating amb. temp.&humi. -25 ~65 ; 20%~90%rh no condensing refer to the derating curve storage temp. & humi. -40 ~85 ; 10%~95%rh no condensing vibration 10 ~ 500hz, 5g 10min./1cycle, period for60min. each along x,y, z axes pulse 20g/11ms pulse ,3 times at each x,y,z axes altitude 5000m safety&emc standards @25 conditions parameter safety standards gb4943 / en60950 for reference withstand voltage i/p-o/p:3.0kvac/10ma; i/p-fg:1.5kvac/10ma; o/p-fg:0 .5kvdc/10ma test time:1min. grounding test test condition 32a 2min. grounding resistance 0.1 ohms. leakage current i/p-grounding 3.5ma i/p-o/p 0.25ma ( 264vac 63hz) isolation resistance i/p-o/p: 10m ohms; i/p-fg : 10m ohms; o/p-fg : 10m ohms emc emission en55032 en55024 class b/fcc part15 emc immunity en61000-4-2,3,4,5,6,8,11 others conditions parameter cooling method cooling by forced air (built-in dc fan) dimension (l*w*h) 199*99*50mm net weight 0.8kg reliabiility characteristics conditions parameter mtbf 100,000hrs at 25 , mil-217 method 2 components stress method design electrolytic capacitor life-time >2years at 50 230vac input 80% output all using 105 long life electrolytic capacitor toppower
tpc/ gkf - 20 0 - xs series www.gztoppower.com tel:0086-20-8 2019000 email:sales2@gztoppower.com page 3 / 4 mechanical dimensions unit:mm toppower
tpc/ gkf - 20 0 - xs series www.gztoppower.com tel:0086-20-8 2019000 email:sales2@gztoppower.com page 4 / 4 block diagram derating curve model selection emi current limiting filter active inrush rectifiers power o.l. p o.l.p pfc&pwm control fan speed rectifiers control fan detection curcuit o.v.p switching & filter i/p fg +v -v ssingle ouputddual output delimiter type series brand toppower delimiter output voltage tp c / gkf - 20 0 C x s ss s rated output power delimiter toppower
|