ver : c_7 update : 2016.09.01 ac-dc power module ajc series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. ( single output ) ajc-3.3s ajc-5s ajc-9s ajc-12s ajc-15s ajc-24s max output wattage ( w ) 26.4w 40w 40w 40w 40w 40w voltage (v.dc.) 3.3v 5v 9v 12v 15v 24v current (ma) max 8000 8000 4444 3333 2666 1667 voltage set accuracy 3% 2% 2% 2% 2% 2% line regulation (typ.) 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% load regulation (1-100%) (typ.) 1% 1% 1% 1% 1% 1% minimum load 1% 1% 1% 1% 1% 1% maximum capacitive load (at 230vac) 60000 uf 40000 uf 7200 uf 8600 uf 6600 uf 1400 uf output efficiency (typ.) 74% 81% 82% 84% 83% 83% model no. ( dual output ) ajc-5d ajc-12d ajc-15d max output wattage ( w ) 40w 40w 40w output 1 output 2 output 1 output 2 output 1 output 2 voltage (v.dc.) +5v -5v +12v -12v +15v -15v current (ma) max 4000 4000 1666 1666 1333 1333 voltage set accuracy 2% 2% 2% line regulation (typ.) 0.5% 0.5% 0.5% load regulation (10-100%) (typ.) 1% (symmetric l oad) 1% (symmetric load) 1% (symmetric load) cross regulation (15-100%) (typ.) 5% 5% 5% minimum load 10% 10% 10% maximum capacitive load (at 230vac) 12000 uf 4400 uf 1000 uf output efficiency (typ.) 81% 83% 83% model no. ( dual output ) ajc-5s12s ajc-5s24s max output wattage ( w ) 40w 40w output 1 output 2 output 1 output 2 voltage (v.dc.) 5v 12v 5v 24v current (ma) max 5000 1250 5000 625 voltage set accuracy 3% 5% 3% 5% line regulation (typ.) 0.5% 5% 0.5% 5% load regulation (25-100%) (typ.) 2% (symmetric load) 6% (symmetric load) 2% (symmetric load) 6% (symmetric load) cross regulation(25-100%) (typ.) 1% 7% 1% 7% minimum load 25% 25% maximum capacitive load (at 230vac) 10000 uf 470 uf 10000 uf 400 uf output efficiency (typ.) 82% 82% key features ? switching power modules for pcb mounting ? fully encapsulated plastic case ? universal input range 90-264vac, 47-440 hz ? regulated output and low ripple and low noise ? isolation class ii ? -40 o c starting ? small size as asc 30watt and 40watt higher wattage ? ce, cb and ul approval ? 3-year product warranty
ver : c_7 update : 2016.09.01 ac-dc power module ajc series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications model no. ( triple output ) ajc-5s12d ajc-5s15d max output wattage ( w ) 40w 40w output 2 output 3 output 1 output 2 output 3 voltage (v.dc.) +12 -12 5 +15 -15 current (ma) max 600 600 5000 500 500 voltage set accuracy 5% 3% 5% line regulation (typ.) 5% 0.5% 5% load regulation (25-100%) (typ.) (symmetric load) 7% 3% 7% cross regulation (typ.) 7% 3% 7% minimum load 25% 25% maximum capacitive load 780 uf 10000 uf 900 uf output efficiency (typ) 80% 81% electrical specifications voltage 90-264 vac or 100-375 vdc frequency (hz) 47-440 hz current (full load) 860 ma max. (115 vac) / 460 ma max. (230 vac) inrush current (<2ms) 30 a max. (115 vac) / 50 a max. (230 vac) input leakage current 0.75 ma max. maximum capacitive load 470-23,000f depending on model ripple & noise 3.3v 50mv of vout / others 1% of vout output hold-up time 10 ms min. over current protection above 105% rated output power over voltage protection zener diode clamp short circuit protection hiccup mode, indefinite (automatic recovery) protection otp 100c isolation input-output (v.ac) 3000v operating temperature -40c?+70c (case temperature max. +95c) storage temperature -40c?+85c temperature coefficient 0.01%/c humidity 95% rh environment mtbf 200,000 h~400,000 h @ 25c dimension (l x w x h) 3.52 x 2.52 x 0.98 inches ( 89.5 x 64.1 x 25.0 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 280 g physical cooling method free air convection agency approvals ce, ul/cul, cb emi (conducted & radiated emission) en 55022 class b safety & emc ems (noise immunity) en 55024 note 1. all specifications valid at normal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 3. it's recommended to add varistor 14s471k at l / n input side in parallel. 4. it's necessary 10r / 15 thermistor at l input side in series connection. 5. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw
ver : c_7 update : 2016.09.01 ac-dc power module ajc series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ( top view ) block diagram derating pin# single dual 5s/12s 5s/24s triple 1 ac in (l) ac in (l) ac in (l) ac in (l) 2 ac in (n) ac in (n) ac in (n) ac in (n) 3 +dc out +dc out +out2 +dc out 4 no pin no pin +out1 +5v 5 -dc out common +out2 rtn common 6 no pin no pin +out1 rtn +5 rtn 7 no connect -dc out no pin -dc out
ver : c_7 update : 2016.09.01 ac-dc power module ajc series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- screw terminal ajc-a2 pin# single dual 5s/12s 5s/24s triple 1 ac in (l) ac in (l) ac in (l) ac in (l) 2 no connect no connect no connect no connect 3 ac in (n) ac in (n) ac in (n) ac in (n) 4 +dc out +dc out +out2 +dc out 5 no connect no connect + o u t 1 + 5 v o u t 6 -dc out common +out2 rtn common 7 no connect no connect + o u t 1 r t n + 5 v r t n 8 no connect - d c o u t no connect - d c o u t
|